Parking Tower
 
 
   
 
Contact: Mr. Lin Tel:+66-945606400
Product Description

Features:

(1) Fully automatic computer control with intuitive touch-panel for fast and easy car parking.
(2) Computerized audio and visual (moving-sign) guiding system in entrance and exit area.
(3) Built-in self-diagnosis system for both parking cell and elevator.
(4) 24-hour security monitoring and alarm system.
(5) Security monitoring system inside the parking tower and in entrance and exit area.
(6) Integrated smoke ventilation and CO2 fire extinguishing system.
(7) Powerful illumination equipment for both interior and exterior of the parking tower.
(8) Emergency backup power system.
(9) Built-in turntable for straight driving in and out without reversing.
(10) Various interlocking mechanisms for safe operation. 
 

Model: MT-S, MT-M, MT-L and MT-XL. Specifications:
 Admissible Car dimensions:
Model MT-S MT-M  MT-L MT-XL
(Small size) (Mid-size) (Mid- to large-size) (Large size)
Max. Length (mm) 4900 5050 5300 5600
Max. Width (mm) 1750(1950) 1750(1950) 1900(2100) 1900(2100)
(w/ Rear view mirror)
Max. Height (mm) 1550 1550 1550 1550
Max. Weight (kg) 1600 1900  2100  2200 standard spec

Specifications:
Model MT-S MT-M  MT-L MT-XL
(Small size) (Mid-size) (Mid- to large-size) (Large size)
Elevator speed 120(130)m/min 120(130)m/min 120(130)m/min 120(130)m/min
Elevator horsepower 18.5kW  22kW 30kW 30kW
Lateral moving speed 30m/min
Lateral horsepower 0.75kW*2
Turntable rotation speed 5rpm
Turntable horsepower  1.5kW 1.5kW 1.5kW  2.2kW
Transport Control Lateral movement: Servo control
Vertical movement: Vector inverter control
MMI Color Touch Panel
Safety Setup Optoelectronic sensors, All-system-go confirmation and Emergency stop button
Guiding Sign Installed in apparent places inside the tower.
Guiding Mirror Size: 900*1800 mm2, may be installed in front of the entrance/exit area or places where appropriate.
Entrance/Exit Door Width(2700/4500mm)*Height (1900mm),2-piece or 4-piece double-slide motor-driven doors.
Fire-fighting equipment Carbon dioxide (CO2)
Power source 380V/220V, 60Hz, 3-phase
Illumination power source 220V/110V, 60Hz, single-phase
Power source for fire- fighting equipment 110V, 60Hz, single-phase
Control mode Fully automatic control mode